← sparkquote.ai

INDIVIDUAL MCP TOOL

voltage_drop

Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).

sparkquote.ainone authenticationAvailability not checked

LIVE ENDPOINT

https://sparkquote.ai/mcp

No auth detected

Connect to this endpoint to inspect the live schema for voltage_drop and invoke it with your own arguments.

Indexed input schema

{}

Risk classification

Potential side effects detected · medium confidence · heuristic, not a guarantee.

  • A tool name or description contains a deletion term.

Parent server

sparkquote.ai

CONNECT WITH APPROVAL

Client installation

Review this server and its permissions before adding it. Secret placeholders must be set locally.

Codex

~/.codex/config.toml

[mcp_servers.sparkquote]
url = "https://sparkquote.ai/mcp"
enabled = true
Claude Code

.mcp.json

{
  "mcpServers": {
    "sparkquote": {
      "type": "http",
      "url": "https://sparkquote.ai/mcp"
    }
  }
}
Claude Desktop

Settings → Connectors → Add custom connector

Name: sparkquote
Remote MCP URL: https://sparkquote.ai/mcp

Add this remote URL as a custom connector in Claude Desktop. Availability depends on the user plan and workspace policy.

Cursor

.cursor/mcp.json

{
  "mcpServers": {
    "sparkquote": {
      "url": "https://sparkquote.ai/mcp"
    }
  }
}
Visual Studio Code

.vscode/mcp.json

Add to Visual Studio Code
{
  "servers": {
    "sparkquote": {
      "type": "http",
      "url": "https://sparkquote.ai/mcp"
    }
  }
}
Generic MCP

Client-specific MCP configuration

{
  "name": "sparkquote",
  "transport": "streamable-http",
  "url": "https://sparkquote.ai/mcp"
}
MCP Inspector

Run the official MCP Inspector locally and enter the indexed Streamable HTTP endpoint.

Related tools

  • wire_size — Minimum conductor size for a circuit: NEC Table 310.
  • watts_to_amps — Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.
  • conduit_fill — Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.
  • box_fill — Minimum outlet box volume from NEC 314.
  • load_calculator — Dwelling service load by the NEC 220.
  • ohms_law — Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.
  • panel_schedule — Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.
  • bid_calculator — Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).