sparkquote.ai

An MCP server providing NEC-based electrical calculators for conductor sizing, voltage drop, current draw, conduit fill, and box fill.

1 endpoint10 known toolsFirst detected October 15, 2026Last detected November 14, 2026

ENDPOINT 1

https://sparkquote.ai/mcp

No auth detected

MCP server metadata

Name
sparkquote
Version
1.0.0
Capabilities
tools
Server instructions

SparkQuote NEC calculators (NEC 2023, NFPA 70). Tools for wire sizing, ampacity, voltage drop, conduit fill, box fill, residential service load, watts to amps, Ohm's law, panel schedules and bid pricing. Each result names the NEC table or section it used and includes the URL of the matching calculator page. Results are code minimums under the stated assumptions: local amendments and the adopted edition can change the answer, and the inspector has the final say.

Known tools 10

wire_size

Minimum conductor size for a circuit: NEC Table 310.

Inferred read-only
voltage_drop

Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).

Potential side effects
watts_to_amps

Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.

Inferred read-only
conduit_fill

Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.

Inferred read-only
box_fill

Minimum outlet box volume from NEC 314.

Inferred read-only
load_calculator

Dwelling service load by the NEC 220.

Inferred read-only
ohms_law

Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.

Inferred read-only
panel_schedule

Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.

Inferred read-only
bid_calculator

Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).

Inferred read-only
nec_ampacity

Allowable ampacity of one insulated conductor from NEC Table 310.

Inferred read-only

CONNECT WITH APPROVAL

Client installation

Review this server and its permissions before adding it. Secret placeholders must be set locally.

Codex

~/.codex/config.toml

[mcp_servers.sparkquote]
url = "https://sparkquote.ai/mcp"
enabled = true
Claude Code

.mcp.json

{
  "mcpServers": {
    "sparkquote": {
      "type": "http",
      "url": "https://sparkquote.ai/mcp"
    }
  }
}
Claude Desktop

Settings → Connectors → Add custom connector

Name: sparkquote
Remote MCP URL: https://sparkquote.ai/mcp

Add this remote URL as a custom connector in Claude Desktop. Availability depends on the user plan and workspace policy.

Cursor

.cursor/mcp.json

{
  "mcpServers": {
    "sparkquote": {
      "url": "https://sparkquote.ai/mcp"
    }
  }
}
Visual Studio Code

.vscode/mcp.json

Add to Visual Studio Code
{
  "servers": {
    "sparkquote": {
      "type": "http",
      "url": "https://sparkquote.ai/mcp"
    }
  }
}
Generic MCP

Client-specific MCP configuration

{
  "name": "sparkquote",
  "transport": "streamable-http",
  "url": "https://sparkquote.ai/mcp"
}
MCP Inspector

Run the official MCP Inspector locally and enter the indexed Streamable HTTP endpoint.

TRUST AND VERIFICATION EVIDENCE

Loading Trust v2 evidence…

Checking the associated registrable domain. The BuiltWith key remains server-side.

Indexed

Evidence is source-attributed and does not guarantee that a third-party server is safe. Risk labels are conservative metadata heuristics.