panel_schedule

Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.

sparkquote.ainone authenticationAvailability not checked

LIVE ENDPOINT

https://sparkquote.ai/mcp

No auth detected

Connect to this endpoint to inspect the live schema for panel_schedule and invoke it with your own arguments.

Indexed input schema

{}

Risk classification

Inferred read-only · medium confidence · heuristic, not a guarantee.

  • No write-capable action terms were found; this is not proof that invocation has no side effects.

Parent server

sparkquote.ai

CONNECT WITH APPROVAL

Client installation

Review this server and its permissions before adding it. Secret placeholders must be set locally.

Codex

~/.codex/config.toml

[mcp_servers.sparkquote]
url = "https://sparkquote.ai/mcp"
enabled = true
Claude Code

.mcp.json

{
  "mcpServers": {
    "sparkquote": {
      "type": "http",
      "url": "https://sparkquote.ai/mcp"
    }
  }
}
Claude Desktop

Settings → Connectors → Add custom connector

Name: sparkquote
Remote MCP URL: https://sparkquote.ai/mcp

Add this remote URL as a custom connector in Claude Desktop. Availability depends on the user plan and workspace policy.

Cursor

.cursor/mcp.json

{
  "mcpServers": {
    "sparkquote": {
      "url": "https://sparkquote.ai/mcp"
    }
  }
}
Visual Studio Code

.vscode/mcp.json

Add to Visual Studio Code
{
  "servers": {
    "sparkquote": {
      "type": "http",
      "url": "https://sparkquote.ai/mcp"
    }
  }
}
Generic MCP

Client-specific MCP configuration

{
  "name": "sparkquote",
  "transport": "streamable-http",
  "url": "https://sparkquote.ai/mcp"
}
MCP Inspector

Run the official MCP Inspector locally and enter the indexed Streamable HTTP endpoint.

Related tools

  • wire_size — Minimum conductor size for a circuit: NEC Table 310.
  • voltage_drop — Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).
  • watts_to_amps — Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.
  • conduit_fill — Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.
  • box_fill — Minimum outlet box volume from NEC 314.
  • load_calculator — Dwelling service load by the NEC 220.
  • ohms_law — Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.
  • bid_calculator — Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)).