calculate_voltage_drop
Use for branch circuits, feeders, long runs, copper/aluminum voltage drop, one-way length, single-phase, and three-phase voltage drop questions.
LIVE ENDPOINT
https://sparkshift.app/mcp
Connect to this endpoint to inspect the live schema for calculate_voltage_drop and invoke it with your own arguments.
Indexed input schema
{}Risk classification
Potential side effects detected · medium confidence · heuristic, not a guarantee.
- A tool name or description contains a deletion term.
Parent server
CONNECT WITH APPROVAL
Client installation
Review this server and its permissions before adding it. Secret placeholders must be set locally.
Codex
~/.codex/config.toml
[mcp_servers.sparkshift-electrical-calculators]
url = "https://sparkshift.app/mcp"
enabled = true
Claude Code
.mcp.json
{
"mcpServers": {
"sparkshift-electrical-calculators": {
"type": "http",
"url": "https://sparkshift.app/mcp"
}
}
}
Claude Desktop
Settings → Connectors → Add custom connector
Name: sparkshift-electrical-calculators
Remote MCP URL: https://sparkshift.app/mcp
Add this remote URL as a custom connector in Claude Desktop. Availability depends on the user plan and workspace policy.
Cursor
.cursor/mcp.json
{
"mcpServers": {
"sparkshift-electrical-calculators": {
"url": "https://sparkshift.app/mcp"
}
}
}
Visual Studio Code
.vscode/mcp.json
Add to Visual Studio Code{
"servers": {
"sparkshift-electrical-calculators": {
"type": "http",
"url": "https://sparkshift.app/mcp"
}
}
}
Generic MCP
Client-specific MCP configuration
{
"name": "sparkshift-electrical-calculators",
"transport": "streamable-http",
"url": "https://sparkshift.app/mcp"
}
MCP Inspector
Run the official MCP Inspector locally and enter the indexed Streamable HTTP endpoint.
Related tools
calculate_wire_size— Use for wire sizing, ampacity derating, continuous load checks, terminal temperature limits, NEC/CEC conductor sizing, and EGC upsizing notes.calculate_conduit_fill— Use for NEC/CEC conduit fill questions, conductor counts, mixed conductor sizes, raceway trade sizes, and the short nipple exception.calculate_box_fill— Use for device box cubic-inch checks, conductor allowances, grounds, NEC clamps/supports, CEC wire connectors, fixture studs/hickeys, and device/yoke counts.calculate_dwelling_load— Use for residential service sizing, standard and optional dwelling load methods, EV loads, HVAC comparison, ranges, dryers, and future growth.calculate_motor_flc— Use for motor full-load current, conductor sizing at 125 percent of FLC, and inverse-time breaker/OCPD sizing questions.calculate_electrical_formulas— Use for formula questions where the user asks for three-phase kW/kVA, energy cost, Ohm's law-style helper math, or electronics reference calculations.calculate_short_circuit— Use for point-to-point available fault-current screening, conductor run reduction, and interrupting-rating planning.calculate_arc_flash— Use for arc-flash awareness screening with fault current, clearing time, working distance, equipment type, and electrode configuration.