Developer Tools
datasheetvend.com
Provides MCP tools for DatasheetVend that list hardware extraction modules for parsing component datasheets into pinouts, ratings, timing, footprints, and related engineering data.
ENDPOINT 1
https://datasheetvend.com/api/mcp
MCP server metadata
- Name
- datasheetvend
- Version
- 1.0.0
Known tools 51
datasheetvend_extract_document_mapBuild the Document Map of a datasheet PDF: a deterministic, machine-readable index of WHERE the topics live (pinout, package, mechanical, electrical, timing, thermal, absolute_max, registers, cautions …) and WHAT each page physically looks like (table / prose / vector_drawing / raster_image / blank / honest unknown), including a per-page geometry census (vector paths, ruling lines, raster coverage).
Inferred read-onlydatasheetvend_read_document_map_instructionsReturn the versioned usage instructions for Document Map consumers: the binding rule (SHA-256 + physical pages), field semantics, the dominant_form action table, and the measured routing discipline.
Inferred read-onlydatasheetvend_inspect_document_pageTier-2 detail for ONE page of an already-mapped datasheet: the full measured anatomy (text metrics, MuPDF geometry census, structural geometry signals), the page's own headings and first lines, and which modules claim the page.
Inferred read-onlydatasheetvend_search_documentFind where the source datasheet behind an extraction job says something: every text token containing the term, with its page and its box on the page in PDF points.
Inferred read-onlydatasheetvend_read_document_pageRead one page of the source datasheet behind an extraction job as positioned text tokens (text and box in PDF points), in reading windows of at most 1500 tokens (token_offset / next_token_offset).
Inferred read-onlydatasheetvend_locate_evidenceFor every extracted value of an extraction job (one module, or all of them), find the exact words on the source datasheet page the extraction cites and return their box: x, y, width, height normalized 0-1 to the page (origin top-left) plus bounds_pt in PDF points.
Inferred read-onlydatasheetvend_list_module_packetsFor each extraction module (pinout, absolute_max, thermal, logic_levels, power_battery, timing, part_decoder, register_map, peripheral_matrix, analog_intelligence, passive_bom, pin_cautions), what its packet holds of the job's parsed datasheet: status (routed, routed_partial, nothing_routed: a statement about routing, never about the part), the target package it is scoped to, notes (what the packet does not do yet, e.
Inferred read-onlydatasheetvend_get_module_packetOne extraction module's packet: the blocks of the parsed datasheet that module needs, in reading order, each with its reasons (which heading, caption or content tag put it there, from which block), table cells and drawings as a crop box plus the exact words inside them, each with its box.
Inferred read-onlydatasheetvend_list_document_sectionsThe section tree of the job's parsed datasheet: each section's id (its heading block), heading text, level and printed number, page and box of the heading, parent section, heading path, block and subsection counts and page span.
Inferred read-onlydatasheetvend_read_document_sectionOne section's blocks in reading order (text, table cells, drawing crop boxes), each with its block id, page and box, in windows (block_offset / next_block_offset, at most 80 blocks or about 40000 characters).
Inferred read-onlydatasheetvend_neighbor_document_sectionThe section after (direction next) or before (direction previous) the given one in reading order.
Inferred read-onlydatasheetvend_read_document_blockOne parsed block whole: type, page, box, text and markdown (each up to 20000 characters), heading, caption, links, its section and heading path, table cells with their boxes (up to 2000) or a drawing's crop box and the exact words inside it with their boxes (up to 400), and how many cross-references it prints or receives.
Inferred read-onlydatasheetvend_read_document_table_rowsOne parsed table's printed rows in print order (row_index 0 = top row; two rows with the same values stay two rows), each with its line text as printed, its cells (cell_id, text, box, row_span, col_span) and the cells spanning down into it (covered_by).
Inferred read-onlydatasheetvend_follow_document_referenceThe cross-references a block prints ('see Table 9', 'Figure 6', 'on page 41'), each resolved: resolution block (the referenced table, figure or heading, with its id, page, box and a text preview), page (only its page is known) or unresolved; the references elsewhere in the document that point at this block; and for a table, its continuation (the table it continues on an earlier page, the tables continuing it, the chain's pages and the caption printed over its first part).
Inferred read-onlydatasheetvend_search_document_blocksCase-insensitive text search over the parsed blocks' text and table cells: each hit gives the block id, page, type, box and a snippet; a table hit also gives the cell's id, row, column and box.
Inferred read-onlydatasheetvend_check_design_valueCheck one design value against every rule DatasheetVend extracted from a datasheet (its pin-cautions rulebook): for example a 4.
Inferred read-onlydatasheetvend_crosscheck_netlistAudit a KiCad netlist against the datasheets your account has extracted with DatasheetVend.
Inferred read-onlydatasheetvend_match_kicad_footprintFind the official KiCad library footprint for chips from their package numbers.
Inferred read-onlydatasheetvend_resolve_part_numberResolve a full ordering code against a datasheet your account already extracted with the part_decoder module: the document's own part-number legend and ordering table, as that run read them.
Inferred read-onlydatasheetvend_estimate_power_budgetEstimate a system's supply current and battery life (not thermal power dissipation) from parts your account extracted: total active current (mA), total standby current (uA), a breakdown per part and battery life on six standard batteries, as the DatasheetVend Workbench POWER tab computes it.
Inferred read-onlydatasheetvend_explain_warningsReport the warnings an extraction raised, grouped and ranked by DatasheetVend's own classifier (the grouper the result page's warnings panel uses).
Inferred read-onlydatasheetvend_diagnose_extractionExplain what happened to an extraction, module by module, from recorded state.
Inferred read-onlydatasheetvend_compare_extractionsCompare the SAME module across 2-4 of your extraction jobs in one aligned table, instead of reading each job.
Inferred read-onlydatasheetvend_search_my_extractionsFind your own (non-archived) extraction jobs by condition: filename words, a module that produced output, jobs with warnings, or jobs waiting on a decision.
Inferred read-onlydatasheetvend_assess_datasheetJudge whether a datasheet PDF is likely to extract well BEFORE you spend credits on it.
Inferred read-onlydatasheetvend_get_part_packBuy one part pack: a component's frozen module outputs (pinout, footprint, limits, timing and the others the manifest lists) as one JSON envelope.
Inferred read-onlydatasheetvend_extract_pinoutExtract a component's pin/pad table from a datasheet PDF as verifiable, provenance-tracked evidence — not raw PDF text to re-interpret.
Inferred read-onlydatasheetvend_extract_thermal_limitsExtract thermal characteristics: junction-to-ambient (θJA) and junction-to-case (θJC) thermal resistance, power dissipation limits, and operating/junction/storage temperature ranges — with the datasheet page where one was recorded.
Inferred read-onlydatasheetvend_extract_absolute_maxExtract the Absolute Maximum Ratings: never-exceed supply/pin voltages, max currents, and storage temperatures.
Inferred read-onlydatasheetvend_extract_logic_levelsExtract DC electrical characteristics: VIH/VIL/VOH/VOL thresholds, Schmitt hysteresis, AND the VCC/VDD operating supply voltage range.
Inferred read-onlydatasheetvend_extract_timing_characteristicsExtract AC timing: setup/hold (tSU, tH), propagation delays, maximum clock frequencies (fMAX), rise/fall times, and bus timing.
Inferred read-onlydatasheetvend_extract_register_mapExtract the register map: memory addresses, reset values, access permissions (RO/RW/W1C), and per-bit field definitions.
Inferred read-onlydatasheetvend_extract_package_dimensionsExtract mechanical package outline dimensions (D, E, A, A1, e, L, b) and a nominal land geometry estimate in the spirit of IPC-7351B (review-level, not a manufacturer land pattern).
Inferred read-onlydatasheetvend_decode_part_numberDecode the ordering nomenclature: per-position suffix meanings (temp grade, package, speed, packaging) and, where the datasheet's ordering information supports it, the enumerated orderable_part_numbers list — the direct answer to 'which/how many orderable part numbers'.
Inferred read-onlydatasheetvend_extract_peripheral_matrixExtract the on-chip peripheral inventory, one row per instance, in 13 classes: serial/communication (UART/USART, SPI, I2C, CAN, USB, Ethernet, SDIO, I2S/SAI), analog blocks (ADC, DAC, comparator, op-amp, voltage reference, temperature sensor), timers and watchdogs, DMA, security/math accelerators (crypto, RNG, CRC), external memory interfaces (FMC/FSMC/EMC, memory-mapped QSPI), display/camera/touch, interrupt controllers, GPIO, clock/reset, low-power modes, debug/trace and device identity.
Inferred read-onlydatasheetvend_extract_analog_specsExtract analog conversion and signal-conditioning specs: ADC/DAC resolution, sampling rates (MSPS/kSPS), channel counts, input-voltage ranges, static non-linearity (INL/DNL), dynamic specs (ENOB, SINAD, SNR, SFDR, THD), operational amplifiers (GBW, slew rate, rail-to-rail, CMRR/PSRR), internal voltage references (nominal voltage, tempco ppm/°C), and operating supply/temp envelopes, plus comparator propagation delay and hysteresis.
Inferred read-onlydatasheetvend_extract_power_domainsExtract power supply domains (VDD/VDDA/VBAT), low-power/sleep modes and their consumption, and battery-backup configuration.
Inferred read-onlydatasheetvend_extract_passive_bomExtract the recommended passive support components: decoupling/bypass capacitors, crystal load caps, and pull-up/down resistors, with their values and the pins they connect to.
Inferred read-onlydatasheetvend_extract_pin_cautionsExtract hardware design cautions: bootstrap/mode-strapping requirements, 5V-tolerant vs 3.
Inferred read-onlydatasheetvend_extract_altium_bundleParse an Altium Designer ASCII footprint export (a text file — NOT a binary .
Inferred read-onlydatasheetvend_search_component_librarySearch DatasheetVend's component library: parts from dozens of manufacturers whose manufacturer datasheet DatasheetVend stores.
Inferred read-onlydatasheetvend_calculate_land_patternEstimate a land pattern from package numbers: a generic IPC-7351-style pad width, pad length and courtyard for a perimeter package (QFN/DFN/SON leadless, or QFP/SOIC/SSOP/TSSOP/SOP gull-wing).
Inferred read-onlydatasheetvend_get_part_pack_manifestSee what DatasheetVend has shelved for a part BEFORE buying: each package variant's part pack, with the modules it holds and the ones it does not (module_count_available of module_count_total), its warnings, the source jobs and the manufacturer datasheet link.
Inferred read-onlydatasheetvend_list_hardware_modulesList all available hardware extraction modules supported by DatasheetVend (KiCad footprints/symbols, Universal Pinout, Thermal Limits, Absolute Maximum Ratings, Timing Characteristics, Logic Levels, Register Maps, Decoupling Passive BOM, Part Number Decoders, etc.
Inferred read-onlydatasheetvend_list_component_twinsList the datasheets in your DatasheetVend account that have a Unified Component Model (UCM) digital twin: the facts DatasheetVend already extracted from each datasheet — pins, supply rails, interfaces, registers and whole-part limits — combined across the extraction runs stored for it.
Inferred read-onlydatasheetvend_get_component_twinRead the Unified Component Model (UCM) digital twin of one datasheet already extracted with DatasheetVend.
Inferred read-onlydatasheetvend_build_component_twinExtract a datasheet with DatasheetVend Fast Extraction and return its Unified Component Model (UCM) digital twin in one call.
Inferred read-onlyCONNECT WITH APPROVAL
Client installation
Review this server and its permissions before adding it. Secret placeholders must be set locally.
Codex
~/.codex/config.toml
[mcp_servers.datasheetvend]
url = "https://datasheetvend.com/api/mcp"
enabled = true
Claude Code
.mcp.json
{
"mcpServers": {
"datasheetvend": {
"type": "http",
"url": "https://datasheetvend.com/api/mcp"
}
}
}
Claude Desktop
Settings → Connectors → Add custom connector
Name: datasheetvend
Remote MCP URL: https://datasheetvend.com/api/mcp
Add this remote URL as a custom connector in Claude Desktop. Availability depends on the user plan and workspace policy.
Cursor
.cursor/mcp.json
{
"mcpServers": {
"datasheetvend": {
"url": "https://datasheetvend.com/api/mcp"
}
}
}
Visual Studio Code
.vscode/mcp.json
Add to Visual Studio Code{
"servers": {
"datasheetvend": {
"type": "http",
"url": "https://datasheetvend.com/api/mcp"
}
}
}
Generic MCP
Client-specific MCP configuration
{
"name": "datasheetvend",
"transport": "streamable-http",
"url": "https://datasheetvend.com/api/mcp"
}
MCP Inspector
Run the official MCP Inspector locally and enter the indexed Streamable HTTP endpoint.
TRUST AND VERIFICATION EVIDENCE
Loading Trust v2 evidence…
Checking the associated registrable domain. The BuiltWith key remains server-side.
Evidence is source-attributed and does not guarantee that a third-party server is safe. Risk labels are conservative metadata heuristics.