← Registry

Security & Testing

complyonsite.com

ComplyOnSite is a compliance and security-focused MCP server, though its current description only displays an error message.

1 endpoint11 known toolsFirst detected October 7, 2026Last detected November 6, 2026

ENDPOINT 1

https://mcp.complyonsite.com/mcp

No auth detected

MCP server metadata

Name
complyonsite
Version
0.4.0
Capabilities
toolsresources
Server instructions

Anonymous read-only tools for people running UK construction and waste work. They cover: List of Waste (EWC) codes for a skip, load or material; waste codes for the US, California, Texas, Australia and Canada; filling in a UK waste transfer note from the details in the conversation, checked against what the note legally needs, with a card to correct it and a link that opens it unsigned; which waste paperwork a movement needs in each UK nation and some other countries; links that open a waste transfer note, hazardous waste consignment note or RAMS ready to fill in, with blank templates and worked examples as PDFs; one person’s daily hand-arm vibration (HAVS) and noise exposure; first-aid cover for a site or workplace; typical vibration and declared noise for types of power tool; retained HSE construction injury statistics; and links to the website tools for work on files or kept records, such as turning a safety data sheet into a workbook, checking a Receipt of Waste workbook or reviewing a RAMS. Each result starts with a plain summary and includes source.url as data; calculator results include a link that opens the same calculation on complyonsite.com. EWC results are candidates rather than waste classifications; exposure estimates do not establish safety; statistics are a retained release rather than a live HSE feed; document links do not create, save, sign, issue or submit records. Only details the person has given go on a note. The server does not provide legal decisions, regulator acceptance, submission to a regulator, live register checks (waste carrier, broker or dealer registration, permits or exemptions; the regulator’s public register answers those), accounts, saved records, maker-model lookup or completed RAMS packs, and it does not read files. Noise action values (80 and 85 dB(A)) compare noise before hearing protection; the 87 dB(A) limit is a separate check at the ear, after protection.

Known tools 11

ewc_search

Find UK List of Waste (EWC) codes for a waste, skip or load from one to three material words such as “plasterboard”, “mixed rubble” or “contaminated soil”, from one or more codes, or from a code prefix.

Inferred read-only
first_aid_requirements

Estimate first-aid cover for each shift from HSE guidance: how many first-aiders or appointed persons, which course, whether the first-aiders already there are enough, and whether a first-aid room is worth having.

Inferred read-only
havs_daily_exposure

Calculate one person’s daily hand-arm vibration (HAVS) exposure from the tools they use and for how long: A(8), HSE points, low/high range, and whether it passes the action value (2.

Inferred read-only
noise_daily_exposure

Calculate one person’s daily noise exposure (LEP,d) from measured task levels (LAeq in dB(A)) and how long each lasts, or from dosemeter readings, and which action value it reaches (80 and 85 dB(A)).

Inferred read-only
construction_injury_statistics

Return a retained HSE series for construction in Great Britain: worker deaths and the rate per 100,000 workers with the long-run trend, kinds of fatal accident such as falls from height, employee deaths, self-reported and RIDDOR-reported injuries, or work-related ill health.

Inferred read-only
power_tool_types

Return how much a type of power tool vibrates and how loud makers declare it, such as an angle grinder, SDS drill or breaker: the median and spread of declared figures across models, the matching HSE vibration category and variants, and HSE in-use noise comparisons where available.

Inferred read-only
waste_paperwork

Return which paperwork a waste movement needs: in the UK from the nation and whether the waste is hazardous, or any listed document by id, including Ireland, the Netherlands, the US, Canada and Australia.

Inferred read-only
start_document

Return an anonymous complyonsite.

Inferred read-only
fill_transfer_note

Fill in a UK waste transfer note from what the person has said.

Potential side effects
waste_code_search

Find waste codes in the US federal hazardous waste list (RCRA), California, Texas, Australia or Canada from one to three material words or a code.

Inferred read-only
site_tools

List the ComplyOnSite website tools for work on a file or kept record: safety data sheet to Excel, Receipt of Waste workbook check, Defra report from a weighbridge export, RAMS review, paper form to phone form, site diary, issues, progress report and register.

Inferred read-only

CONNECT WITH APPROVAL

Client installation

Review this server and its permissions before adding it. Secret placeholders must be set locally.

Codex

~/.codex/config.toml

[mcp_servers.complyonsite]
url = "https://mcp.complyonsite.com/mcp"
enabled = true
Claude Code

.mcp.json

{
  "mcpServers": {
    "complyonsite": {
      "type": "http",
      "url": "https://mcp.complyonsite.com/mcp"
    }
  }
}
Claude Desktop

Settings → Connectors → Add custom connector

Name: complyonsite
Remote MCP URL: https://mcp.complyonsite.com/mcp

Add this remote URL as a custom connector in Claude Desktop. Availability depends on the user plan and workspace policy.

Cursor

.cursor/mcp.json

{
  "mcpServers": {
    "complyonsite": {
      "url": "https://mcp.complyonsite.com/mcp"
    }
  }
}
Visual Studio Code

.vscode/mcp.json

Add to Visual Studio Code
{
  "servers": {
    "complyonsite": {
      "type": "http",
      "url": "https://mcp.complyonsite.com/mcp"
    }
  }
}
Generic MCP

Client-specific MCP configuration

{
  "name": "complyonsite",
  "transport": "streamable-http",
  "url": "https://mcp.complyonsite.com/mcp"
}
MCP Inspector

Run the official MCP Inspector locally and enter the indexed Streamable HTTP endpoint.

TRUST AND VERIFICATION EVIDENCE

Trust Data Available

BuiltWith Trust API v2 evidence for complyonsite.com was fetched 2026-11-17T14:17:43.027Z.

Trust status Trusted

complyonsite.com is assessed as Trusted: Domain runs a meaningful technology spend, consistent with a real business.

Indexed

Evidence is source-attributed and does not guarantee that a third-party server is safe. Risk labels are conservative metadata heuristics.