← Registry

Analytics

carbonara-co2.org

Calculates logistics shipment greenhouse gas emissions and generates ISO 14083/GLEC-aligned emissions reports with vehicle and location lookup support.

1 endpoint8 known toolsFirst detected October 19, 2026Last detected November 18, 2026

ENDPOINT 1

https://carbonara-co2.org/mcp

No auth detected

MCP server metadata

Name
sootcase
Version
1
Capabilities
resourcestools
Server instructions

Sootcase calculates freight transport greenhouse gas emissions (kg CO2e) following the GLEC Framework v3.3 and ISO 14083:2023. How to use it: 1. For each leg of the trip you need the mode (road, rail, sea, air, inland_waterway), a vehicle type, and where it goes. Use find_places to turn place names into coordinates or UN/LOCODE/IATA codes; Sootcase routes the distance itself (roads, railways, waterways, sea lanes). Use list_vehicle_types to pick vehicle types; the short aliases (hgv, hgv_artic_33t, van, freight_train, container_ship, container_barge, air_freight, roro, ...) cover most cases. 2. Call calculate_shipment for one shipment, calculate_shipments for several, emissions_report for an ISO 14083 style report over many, compare_scenario for what-if changes (road to rail, electric trucks, other fuels, loads), recommend_routes to find route changes that lower each shipment's emissions (rail, waterway, short sea, sea or rail instead of air, other ports, fuller loads). 3. Results include ghg_protocol: for a company buying the transport all of it is scope 3 (category 4 if it pays, 9 for sold products it doesn't pay to move); for the operator of the vehicles scope 1, scope 2 and scope 3 category 3. Every result says how it was calculated: the distance and how it was found, the factor and its source, any distance adjustment, the method and data type, notes on road legs Sootcase added or ends it moved to a port or terminal, and warnings. calculate_shipment adds a step-by-step calculation sheet with the GLEC page and ISO clause behind each step. Read it, and show the user the parts that matter. Be careful with: - Truck load: load_factor is a share of DESNZ's average full load (17.9 t for an articulated truck), not of the truck's rated payload as in GLEC or EcoTransIT. If the user knows the tonnes on the truck, pass load_tonnes instead. - Assumptions: tell the user which vehicle types and loads you chose and why. - Results are calculations following GLEC/ISO 14083, not certified figures; never declare ISO 14083 conformity for the user. get_methodology explains everything in detail.

Known tools 8

calculate_shipment

Calculates one shipment's greenhouse gas emissions (kg CO2e: well-to-wheel, tank-to-wheel, well-to-tank) following the GLEC Framework v3.

Inferred read-only
calculate_shipments

Calculates several shipments at once, each like calculate_shipment.

Inferred read-only
emissions_report

Calculates shipments and returns a report with the basic content ISO 14083 asks for at the level of transport services (GLEC v3.

Inferred read-only
compare_scenario

Calculates the shipments as they are and with changes, with the same method (GLEC v3.

Inferred read-only
recommend_routes

For each shipment, tries road legs on rail, inland waterway and short sea, air legs by sea or rail, other sea ports, (when a load is given) fuller loads, and on the same route larger, electric and bio-LNG trucks (GLEC v3.

Inferred read-only
find_places

Finds cities, sea and inland ports, rail and road terminals, inland depots, border crossings and airports by name, UN/LOCODE or IATA code, with coordinates, from an embedded list (GeoNames, UN/LOCODE, OurAirports).

Inferred read-only
list_vehicle_types

Lists the vehicle types (and their short aliases) with their emission factors: g CO2e per tonne-km tank-to-wheel and well-to-tank, the distance type they are per, source and year, and for trucks the load model's payload (what load_factor 1 means).

Inferred read-only
get_methodology

Explains the whole method: scope (WTW, TTW, WTT), inputs, the five calculation methods with formulas, how distances are routed, distance adjustment factors, added road legs, the emission factor datasets and their sources and limitations, data quality, what every result field means, errors, and how to present results.

Inferred read-only

CONNECT WITH APPROVAL

Client installation

Review this server and its permissions before adding it. Secret placeholders must be set locally.

Codex

~/.codex/config.toml

[mcp_servers.sootcase]
url = "https://carbonara-co2.org/mcp"
enabled = true
Claude Code

.mcp.json

{
  "mcpServers": {
    "sootcase": {
      "type": "http",
      "url": "https://carbonara-co2.org/mcp"
    }
  }
}
Claude Desktop

Settings → Connectors → Add custom connector

Name: sootcase
Remote MCP URL: https://carbonara-co2.org/mcp

Add this remote URL as a custom connector in Claude Desktop. Availability depends on the user plan and workspace policy.

Cursor

.cursor/mcp.json

{
  "mcpServers": {
    "sootcase": {
      "url": "https://carbonara-co2.org/mcp"
    }
  }
}
Visual Studio Code

.vscode/mcp.json

Add to Visual Studio Code
{
  "servers": {
    "sootcase": {
      "type": "http",
      "url": "https://carbonara-co2.org/mcp"
    }
  }
}
Generic MCP

Client-specific MCP configuration

{
  "name": "sootcase",
  "transport": "streamable-http",
  "url": "https://carbonara-co2.org/mcp"
}
MCP Inspector

Run the official MCP Inspector locally and enter the indexed Streamable HTTP endpoint.

TRUST AND VERIFICATION EVIDENCE

Loading Trust v2 evidence…

Checking the associated registrable domain. The BuiltWith key remains server-side.

Indexed

Evidence is source-attributed and does not guarantee that a third-party server is safe. Risk labels are conservative metadata heuristics.